Open the Message Configuration for MXBUS Modules dialog to configure the messages sent by connected MXBUS modules. Upon detecting specific events, an MXBUS module can send messages using the MxMessageSystem; in turn, the module can also execute a specific action upon receiving a corresponding message.
Open the Manage MxBus Modules dialog and make sure that the attached MxBus modules have been activated and that the firmware is up-to-date.
For an introduction and examples on this subject, please see the Technical Note: MxMessageSystem on the MOBOTIX website in the Support > MxMedia Library > Compact Guides section.
All elements and the available settings on this page are explained using tool tips (bubble help). You will see them when you hold the mouse over an element (without clicking).
First, load the configuration from the attached modules by clicking on the Load connected devices from configuration button.
Set the MxMessageSystem names in the Edit Messages section.
A valid MxMessageSystem name must follow these rules:
Must start with a letter.
Must not contain spaces, tabs or the "/
", "%
" or ".
" characters.
Must not be longer than 31 characters.
Note that all entries are case-sensitive. Use the New message and Remove buttons to create new messages and to delete existing ones, respectively. Note that you can only remove a message, if it is not used in any device configuration. When leaving an input field, all messages are stored temporarily on this page and are used to fill the dropdown fields in the configuration forms of all devices. Note that the messages are not yet written to any device configurations.
You can set a message range for every message. This range specifies where to distribute the message. The scope of the ranges is defined as follows:
Global: across all cameras within the current LAN
Local: within the camera (not transferred via the network)
Internal: distribute to all devices on the MxBus
A message can contain parameters and can thus be used to transmit values. The "Parameter" operating mode will be selected automatically depending on the specified configuration. Every message will get a specific signature according to the parameter types that are transmitted. The message dropdown fields are automatically filled and updated using only messages of the same type (i.e., the same signature).
After loading the configuration, the dialog lists all discovered MxBus modules in separate sections below the message section. Depending on the features of the module, the corresponding form section contains subsections for configuring the function components that are available in that module. These can be, for example:
The configuration sections for inputs are present if the module has inputs. Add creates a new line for configuring the current input. To delete a configuration line, click on the corresponding Remove button. Use the first dropdown edge type to set either the desired edge trigger (falling, raising, both), a level period or a parameter. The other selection fields are filled according to the first selection:
When using an edge trigger, the second dropdown field contains the messages that will be triggered.
When using Level period, you need to select the type of level to test for (high, low) and the duration that will trigger a message. In addition, you can set a dead time that can be used to set a pause before sending the next message.
When using a parameter, the second dropdown field contains messages that correspond to the signature, and which can be used to transmit the input state.
The configuration sections for outputs are present if the module has outputs. Add creates a new line for configuring the current output. To delete a configuration line, click on the corresponding Remove button. The first dropdown field shows the generated message names that will be executed when receiving the message. The second dropdown field shows the action to be executed; depending on the selection, more fields will be displayed.
Off: When receiving the message, switches the output off (opens the output).
Lock prevents changes in the output state by any timers.
On: When receiving the message, switches the output on (closes the output).
Lock prevents changes in the output state by any timers.
Toggle: When receiving the message, toggles the output.
Lock prevents changes in the output state by any timers.
Timer: Allows settings a switching time in seconds. The output will be switched to the specified state On or Off for this duration.
Lock prevents changes in the output state while the timer is running.
Parameter: Changes the initial state of the output depending on the parameter contained in the received message.
The KeypadRFID and BellRFID modules can trigger messages when specific RFID cards are presented. To use this feature, you need to add the unique identifier (UID) of the card on the text field. The UID is printed on the back of the card in the center and it can have up to 16 characters in hexadecimal notation (0−9, A−F):
49131 047C18C2022C80 48315
For modules with the ability for audio feedback, you can add/remove messages and the corresponding feedback types (error, success, alarm).
For modules with the ability for visual feedback, you can add/remove messages and the corresponding feedback types (error, success, alarm).
For modules such as the BellRFID, you can configure messages for the available edge triggers in the sections of the corresponding bell button. When using the Parameter setting, the message will transmit the state of the bell buttons as a parameter. Accordingly, you can only select messages that correspond to the signature (sea also under Managing Messages).
The KeypadRFID module has its own configuration section. Its purpose is to map number codes to different messages. Every number code can have up to 16 digits.
The MX-GPS-Box has a temperature sensor, an illumination sensor and a GPS sensor (date and time, position). Since it receives precise time and date information from the GPS satellites, you can use the MX-GPS-Box as camera time server. Please note that the MX-GPS-Box needs to run in classic mode for this purpose. There are two operating modes for the temperature and illumination sensors: Status and Threshold.
In Status mode, the measured values of the sensors can be attached as parameters to the message that will be sent. The message can be sent either using a timer after the specified time in seconds has passed or when receiving the selected message. The default time span for the timer is five minutes (300 seconds); this will prevent the message from being sent too often.
In Threshold mode, you can specify how the threshold or a value range are to be interpreted. To set a threshold, you can use either the Above or the Below comparison type. Note that − in this case − the lower and the upper threshold need to be identical. To set a value range, you can use either the Inner or the Outer comparison type. Enter sensible values for the upper and the lower thresholds. You can send the values of the GPS sensor together with a message. The message can be sent either using a timer after the specified time in seconds has passed or when receiving the selected message. The default time span for the timer is five minutes (300 seconds); this will prevent the message from being sent too often.
The MxMultiSense has sensors for measuring temperature, illumination and sound volume as well as an additional PIR (passive infrared) sensor. There are two operating modes for the temperature and illumination sensors: Status and Threshold.
In Status mode, the measured values of the sensors can be attached as parameters to the message that will be sent. The message can be sent either using a timer after the specified time in seconds has passed or when receiving the selected message. The default time span for the timer is five minutes (300 seconds); this will prevent the message from being sent too often.
In Threshold mode, you can specify how the threshold or a value range are to be interpreted. To set a threshold, you can use either the Above or the Below comparison type. Note that − in this case − the lower and the upper threshold need to be identical. To set a value range, you can use either the Inner or the Outer comparison type. Enter sensible values for the upper and the lower thresholds. The PIR and sound volume sensors can trigger messages of the specified trigger values (in percent) are exceeded.
The MX-Proximity-Box can trigger messages when detecting movements. The Recurrence time specifies the time to pause before a new message can be sent. Note that you can set the sensor range to either Near or Far. In addition, you can use a movement profile, which combines preset sensor values for amplitude, approach speed and escape speed. These values can be customized when using the Custom profile mode.
Since the speed of approaching or leaving objects can only be measured properly with speeds of up to 15 kph/9.3 mph, the Distance slider will be deactivated for higher speeds.
Once you have finished configuring the modules, you can save the current module's configuration by clicking on the Write configuration button at the bottom of the module section. In order to save the configuration of all modules at once, click on Transfer entire configuration at the bottom of the dialog.
In order to load the entire configuration, click on the Load connected devices from configuration button at the bottom of the dialog. The form shows the corresponding modules and the configuration sections. Note that you can also load individual module configurations. This will only update the corresponding device section of the dialog.
Click on the Create default configurations for all devices button at the bottom of the dialog to create a configuration with preset values. This will create configuration sections for all attached modules with appropriate default values and the corresponding messages. Note that you can do this manually for individual modules.
You can reset every module to its factory default settings. This will discard all configuration changes for the device made in this dialog. You can either discard the changes of all modules at the same time (click on Factory Defaults at the bottom of the page) or for a single module (Factory Reset at the bottom of a device section).
Fare clic sul pulsante Imposta per attivare le impostazioni e salvarle fino al prossimo riavvio della videocamera.
Fare clic sul pulsante Default per caricare i valori di default di questa finestra di dialogo (opzione non presente in tutte le finestre di dialogo).
Fare clic sul pulsante Ripristina per annullare le modifiche più recenti che non sono state memorizzate in modo permanente nella videocamera.
Fare clic sul pulsante Chiudi per chiudere la finestra di dialogo. Durante la chiusura della finestra di dialogo il sistema verifica eventuali modifiche nella configurazione. Se le rileva chiede di memorizzare in modo permanente l'intera configurazione.